We offer a wide range of chiller systems designed for various industrial applications. Our products include:
3kW ~ 3000kW / Outlet temperature: 7°C ~ -85°C / Air-cooled, water-cooled, screw type, scroll type, heat pump chiller, modular chiller.
Key Features of the Chiller:
1. Temperature Range: 7°C to -85°C
2. Cooling Capacity Range:
- 1RT to 1000RT
- 5.2kW to 3520kW
- 12,010 Btu to 12,010,240 Btu
- 3,027.2 Kcal to 3,027,200 Kcal
3. Refrigerants Available: R22, R407C, R410A, R404A, R134A, R507C
4. We offer multiple types of water chillers and can also customize according to your specific needs.
Model | WD- | ||||||||||||||||||||||||
UNIT | 188.1WSM3 | 220.1WSM3 | 235.1WSM3 | 260.1WSM3 | 260.1WSM3 | 290.1WSM3 | 335.1WSM3 | 372.1WSM3 | 400.1WSM3 | 445.1WSM3 | |||||||||||||||
Cooling capacity | Btu | 641,456.00 | 750,640.00 | 801,820.00 | 887,120.00 | 955,360.00 | 989,480.00 | 1,143,020.00 | 1,269,264.00 | 1,364,800.00 | 1,518,340 | ||||||||||||||
RT | 53.41 | 62.50 | 66.76 | 73.86 | 79.55 | 82.39 | 95.17 | 105.68 | 113.64 | 126.42 | |||||||||||||||
Kw | 188.00 | 220.00 | 235.00 | 260.00 | 280.00 | 290.00 | 335.00 | 372.00 | 400.00 | 445.00 | |||||||||||||||
×10â´Kcal/h | 16.00 | 19.00 | 20.00 | 22.00 | 24.00 | 25.00 | 29.00 | 32.00 | 34.00 | 38.00 | |||||||||||||||
Control mode | PLC automatic control | ||||||||||||||||||||||||
Power source | 380V/3N/50HZ | ||||||||||||||||||||||||
Compressor | Type | 5-6 asymmetric semi-hermetic twin screw compressors | |||||||||||||||||||||||
Startup type | Y-â–³ | ||||||||||||||||||||||||
Energy regulation | 0-12.5%-25%-37.5%-50%-62.5%-75%-87.5%-100% | ||||||||||||||||||||||||
Qty | 1 | ||||||||||||||||||||||||
Input power | KW | 81.70 | 94.90 | 100.20 | 108.50 | 116.80 | 120.60 | 141.70 | 157.20 | 166.90 | 184.00 | ||||||||||||||
Operation Current | A | 142.20 | 165.10 | 174.30 | 188.80 | 203.20 | 209.80 | 246.60 | 273.50 | 290.40 | 320.20 | ||||||||||||||
Condenser | Type | High efficiency copper dry type shell-and-tube heat exchanger | |||||||||||||||||||||||
Water pipe connection | Â | DN100 | DN125 | DN150 | |||||||||||||||||||||
Cooling Water Flow | m³/h | 61.30 | 71.50 | 76.20 | 83.70 | 90.20 | 93.30 | 108.30 | 120.20 | 128.80 | 142.90 | ||||||||||||||
Water pressure | kpa | 58.00 | 58.00 | 65.00 | 70.00 | 70.00 | 71.00 | 71.00 | 72.00 | 72.00 | 72.00 | ||||||||||||||
Evaporator | Type | Horizontal shell-and-tube / Coil type high efficiency copper heat exchanger | |||||||||||||||||||||||
Water pipe connection | Â | DN80 | DN100 | DN125 | |||||||||||||||||||||
Freezing water Flow | m³/h | 40.00 | 47.50 | 50.00 | 55.00 | 60.00 | 62.50 | 72.50 | 80.00 | 85.00 | 95.00 | ||||||||||||||
Water pressure | kpa | 58.00 | 58.00 | 67.00 | 72.00 | 72.00 | 72.00 | 72.00 | 72.00 | 72.00 | 73.00 | ||||||||||||||
Refrigerant | Type | R22 | |||||||||||||||||||||||
kg | kg | 64.00 | 75.00 | 80.00 | 89.00 | 96.00 | 99.00 | 114.00 | 127.00 | 136.00 | 152.00 | ||||||||||||||
Safety protection | High and low pressure protection; over temperature protection; overload protection; phase sequence protection, etc. | ||||||||||||||||||||||||
Dimensions (L*W*H) | Length | mm | 3225 | 3225 | 3225 | 3505 | 3605 | 3605 | 3720 | 3720 | 3720 | 3930 | |||||||||||||
Width | mm | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | ||||||||||||||
Height | mm | 1830 | 1830 | 1880 | 1880 | 1950 | 1980 | 1880 | 1950 | 1970 | 2020 | ||||||||||||||
Net Weight | kg | 1970 | 2190 | 2440 | 2480 | 2650 | 2950 | 3080 | 3300 | 3470 | 3620 | ||||||||||||||
Operating weight | kg | 2190 | 3380 | 2570 | 2740 | 2950 | 3210 | 3330 | 3570 | 3810 | 3930 |
Note:
1. Freezing water inlet temperature: -10°C, freezing water outlet temperature: -15°C; cooling water inlet temperature: 30°C, cooling water outlet temperature: 35°C;
2. Temperature conditions: Freezing water outlet temperature range: 5°C–15°C, cooling water inlet temperature range: 19–33°C;
3. Safe operating range: Freezing water inlet temperature: 9°C–20°C;
4. The compressor used is a closed turbine imported from Europe and the USA, with superior performance and strong resistance to surges;
5. Nominal operating conditions in the evaporator and condenser water side fouling factor of 0.018 m²°C/kW, condenser water side fouling factor of 0.044 m²°C/kW;
6. The evaporator and condenser water side are designed to withstand a pressure of 1.0MPa;
7. The actual head of the host is the pump head minus the head losses within the host;
8. In addition to the specifications and requirements, we can provide non-standard products based on customer needs.
About Winday:
Winday Industrial is a professional company engaged in the research and development, manufacturing, and sales of industrial refrigeration equipment, as well as refrigeration system design and installation services.
Our commitment to product quality is reflected in "efficiency, stability, and energy-saving progress."
We ensure excellence in manufacturing processes through strict control and thorough testing.
Our refrigeration system designs undergo repeated research, experiments, and feasibility studies to provide customers with optimized cooling solutions and equipment.
Mobile Asphalt Mixing Plant is a convenient, efficient and mobile asphalt mixture production equipment, which is suitable for all kinds of road construction and maintenance projects. It has the characteristics of strong mobility, quick installation and easy operation, and can provide high quality asphalt mixture for the project and improve the construction efficiency.
Mobile Asphalt Mixing Plant is mainly composed of mixing host, dosing system, fuel system, support device and dust removal system. Among them, the mixing machine is the core part, which is responsible for mixing various raw materials evenly to produce high-quality asphalt mixture. The dosing system is responsible for adding various raw materials to the mixing machine in a certain proportion. The fuel system powers the entire device, usually using diesel or gasoline. The support unit includes four wheels and a suspension system that allows the device to travel and operate in a variety of terrain conditions. The dust removal system is responsible for collecting dust and exhaust gas generated during the production process to ensure a clean working environment and air quality.
The working process of the mobile asphalt mixing station mainly includes the following steps: First, the various raw materials are prepared and added to the mixing machine through the dosing system. Next, the mixer machine starts to work, mixing the raw materials evenly to produce the asphalt mixture. The asphalt mixture is then transported to the construction site for road paving or maintenance. In the whole process, the operation of the mobile asphalt mixing plant is simple and convenient, and it can be quickly deployed and moved, which greatly improves the construction efficiency.
Compared with the traditional fixed asphalt mixing plant, the mobile asphalt mixing plant has the following advantages: First, it has the characteristics of strong mobility and rapid deployment, and can adapt to a variety of complex terrain and construction environment. Secondly, the installation and disassembly of the mobile asphalt mixing plant is very convenient, and the transfer and installation of the equipment can be quickly completed, reducing the construction time. In addition, the operation of the mobile asphalt mixing plant is simple and easy to maintain, reducing the skill requirements of the operator and maintenance costs.
In short, the mobile asphalt mixing plant is an efficient, convenient and mobile asphalt mixture production equipment, which is suitable for all kinds of road construction and maintenance projects. It has many advantages, can provide high quality asphalt mixture for engineering, improve construction efficiency, and has a wide range of application prospects.
Recycled Asphalt Mixing Plant,Asphalt Mixing Facilities,Stationary Asphalt Mixing Plant,Asphalt Mixing Facilities Stationary
BituRock Science & Technology (Jiangsu) CO., LTD , https://www.biturockplant.com