Large Stage with Dual-Hand Adjustment
â—‹ To address the limitations of traditional horizontal guide rails, the new stage features a dual-direction linear drive mechanism. This design prevents overload at the end of the rails, enhancing the rigidity and performance of the stage.
â—‹ The stage handle can be placed on either side according to user preference. The X-Y axis adjustment is designed at a low position for comfortable handling.
○ Two slides can be securely held using damping-type double clips, making comparative studies easier. The moving range is 80mm × 55mm, with a precision of 0.1mm.
â—‹ The stage surface is treated with special craftsmanship to resist corrosion and friction. The arc-shaped platform design reduces stress concentration and minimizes damage from impacts.
â—‹ A light barrier is included to reduce stray light, improving image contrast during fluorescence observation.
Modular Frame for Enhanced Compatibility
â—‹ The NK-X50 is designed with a modular structure, separating the cross arm and main body to improve compatibility between biological and fluorescence systems.
Highly Sensitive Coaxial Fine Adjustment
○ The coaxial focus mechanism uses a two-stage drive system with adjustable tension and a top limit stop. It offers a coarse adjustment range of 25mm and fine precision of 1μm, allowing accurate focusing and precise measurement.
Multi-Ratio Viewing Head
â—‹ The NK-X50 viewing head offers multiple splitting ratios. With a wide beam imaging system, it provides a 26.5mm super-wide field of view.
â—‹ The trinocular head with inverted image allows splitting ratios of 100:0, 20:80, or 0:100. This enables both eyepiece and camera use simultaneously by directing 20% of the light to the eyepiece and 80% to the camera.
â—‹ The erect image trinocular head supports splitting ratios of 100:0 or 0:100, with sample movement direction matching the observed direction.
P/N | Optical System | Description | Availability |
NK-X50 | Viewing Head | Inverted image, 30° inclined gemel trinocular head, interpupillary distance: 50–76mm; splitting ratio R:T=100:0, 20:80, or 0:100 | ○ |
NK-X50EI30 | Erect image, 30° inclined gemel trinocular head, interpupillary distance: 50–76mm; splitting ratio R:T=100:0 or 0:100 | ||
PLN10X25T | Eyepiece | High eyepoint wide field plan eyepiece PL10X25mm, diopter adjustable | â—‹â—‹ |
PLN10X25TR | High eyepoint wide field plan eyepiece PL10X25mm, with reticle, diopter adjustable | ||
PLN10X26.5T | High eyepoint wide field plan eyepiece PL10X26.5mm, diopter adjustable | ||
OIPF4 | Objective | Plan semi-apochromatic fluorescence objectives 4X, 0.13NA, WD: 16.43mm | â—‹ |
OIPF10 | Plan semi-apochromatic fluorescence objectives 10X, 0.30NA, WD: 8.13mm | â—‹ | |
OIPF20 | Plan semi-apochromatic fluorescence objectives 20X, 0.50NA, WD: 2.03mm | â—‹ | |
OIPF40 | Plan semi-apochromatic fluorescence objectives 40X (Spring), 0.75NA, WD: 0.74mm | â—‹ | |
OIPF100 | Plan semi-apochromatic fluorescence objectives 100X (Spring & Oil), 1.28NA, WD: 0.18mm | â—‹ | |
NQ5 | Nosepiece | Quintuple nosepiece (with DIC slot) | |
NS6 | Sextuple nosepiece | â—‹ | |
NS7 | Septuple nosepiece | ||
NK-X50FRA | Frame | Biological frame (transmitted), low-position coaxial coarse and fine adjustment, coarse adjustment distance: 25mm; fine precision: 0.001mm. Built-in 100–240V AC transformer, intensity adjustable via digital control, includes transmitted filters LBD/ND6/ND25 | ○ |
NK-X50STA | Stage | Double-layer mechanical stage, size: 187mm × 168mm; moving range: 80mm × 55mm; precision: 0.1mm; two-way linear drive, tension adjustable | ○ |
NK-X50CON | Condenser | Swing-out achromatic condenser (N.A. 0.9) | â—‹ |
NK-X50MLH | Lamp House | 12V/100W halogen lamp house for transmitted light, center pre-set, intensity adjustable | |
HB-12-100 | 12V/100W halogen lamp (PHILIPS 7724) | ||
NK-X50C0.35 | Other Accessories | Camera adapter: 0.5X focusing C-mount | |
NK-X50C0.65 | Camera adapter: 0.65X focusing C-mount | ||
NK-X50C1 | Camera adapter: 1X focusing C-mount | ||
Non-fluorescent oil | â—‹ | ||
High precision micrometer, scale value 0.01mm | |||
Hexagon wrench | â—‹ |
Customizable High Quality Aluminium Tube Coiled,Source factory stock,Customizable High Quality Aluminium Tube Coiled,High Quality Aluminium Tube For Heat Exchanger,High quality Aluminium Tube Coiled
Our company has always had strict quality control standards in the market of refrigeration and heat exchange equipment, focusing on providing customised services to our customers. Not only do we have high requirements for the selection of raw materials, but we also keep up to date with the latest production processes and have high testing standards.
Our company mainly produces products for:Fin Evaporator.Fin Type Condenser.Capillary Tube. Coolant Reservoir.Plate Reinforcement Parts.Stamped Parts.Aluminum Tube.Instrument Testing Equipment.
Aluminum Tube,Rectangular Aluminum Tube,Aluminium Tube Coiled,Customizable Rectangular Aluminum Tube
Xinxiang Yukun Refrigeration Technology Co.Ltd , https://www.yukunevaporator.com