Cooling system for communication cabinet for closed area
Description
SANDA's 200 W DC solid state air conditioner models are designed to cool your electronic and electrical controls,instruments, computer terminals, printers, telecommunications equipment, surveillance devices, cameras, laser and optical equipment and many other electronics in variety of environments. Our electronic cabinet cooler is designed for use with a wide range of enclosures and transit cases. Models are available for both indoor and outdoor use in DC power configurations. Coolers feature corrosion-resistant stainless steel construction. All are available with a variety of options.
Â
Features:Â
• Extremely reliable solid state construction with long lifespan
• Maintenance free design with no moving components (other than fans)
• No compressor, refrigerant or filters
• Compact size, lightweight, convenient to install and operate
• Construction (Type 304 stainless steel) for indoor or outdoor use
• Standard models to 55°C (High ambient models avail.)
• Flush-mount or recessed-mount installation
• Recommended for vertical mounting only
• DC power configurations
• Complete 12 month warranty
Optional features:
• Supplemental heating capability
• Condensate drip pan with fittings and drain tubing
• Extension frame for flush mounting on outside of cabinet
• Rain shroud - vertical mount
• AC power supply (220VAC)
• Digital temperature controller (remote mount)
• Powder coated aluminum construction
No |
Parameters |
Model No. |
||||
SDC2-200 |
SDC2-300 |
|||||
1 |
Cooling capacity |
W |
200 |
300 |
||
2 |
Heating capacity |
W |
200 |
300 |
||
3 |
Rated voltage |
V |
DC48 |
|||
4 |
Rated power |
W |
450 |
600 |
||
5 |
Rated current |
A |
8.5 |
13.6 |
||
6 |
Internal circulation air flow rate |
m3/h |
350 |
360 |
||
7 |
External circulation air flow rate |
m3/h |
         600 |
         640 |
||
 8 |
 Working range |
°C |
-20~55 |
|||
RH |
10%~95% |
|||||
9 |
Cooling/Heating |
Cooling and heating intelligent exchanging |
||||
10 |
 Protection class |
IP55 |
||||
  11 |
 Dimension |
Width |
 mm |
250 |
250 |
|
Depth |
285 |
285 |
||||
Height |
400 |
400 |
||||
12 |
Noise |
dB(A) |
 60 |
60 |
Working Principle
How to install?
A. Embedded the door mounted TEC air conditioner into the open hole from the outside of the cabinet to ensure the TEC air conditioner's mounting flange match the cabinet's installation position.
B. Use 16* M4 phillips screws sequentially align the mounting holes on the mounting flange to fix and tighten it.
C. Check the mechanical installation of the cabinet TEC air conditioner, and do electrical installation after determining correct.
Application
Company Information
Your Advantages with Sanda Electronic:
1) ISO 9001:2008 audited factory, Patented design
2) 12 years R&D and manufacturing experience for dehumidifier; Cabinet air conditioner; Protection relay; Digital Meter; Temperature and humidity controller etc
3) ODM and OEM are warmly welcomed
4) Quality guarantee, 1Â years warranty
5) 7/24h service, better pre-sale and after-sale service.
6) Professional suggestions, help you realize your goals and boost your sustainable development.
Contact Sanda:
Sara Yao
Cell+86 18874731668
 Â
Continuous Waste Oil Distillation Plant
The Continuous Waste Oil Distillation Plant is used to refine waste engine oil, crude oil and fuel oil after pyrolysis process into diesel grade oil, gasoline or and base oil. The daily capacity of this plant is about 10-300 tons.
Advantages of Continuous Waste Oil Distillation Plant
1. Unique manufacturing and technology with our own formula of our equipment in China.
2. High oil output, about 80%-90%.
3. Good quality end product oil as the substitution of standard diesel oil in usage.
4. Security:
A. Adopting automatic submerged-arc welding technology
B. All of the welding will be detected by the ultrasonic nondestructive testing method to ensure the welding quality and the welding shape.
C. Equipped with anti-explosive device, safety valves, emergency valves, pressure and temperature meters, as well as the alarming system.
5. Environmental-friendly:
A. Emission Standard: Adopting special gas scrubbers to remove acid gas and dust from smoke.
B. Smell during operation: Fully enclosed during the operation
C. Water pollution: No pollution at all.
6. Energy conservation and low cost on operation:
Special covers of the reactors and chambers can keep hot during the heating in good efficiency as well as the direct heating system to save energy and cost.
No. |
Item |
Technical Parameter |
1 |
Suitable Raw Material |
used oil, pyrolysis fuel oil, crude oil |
2 |
Structure |
Continuous Vertical |
3 |
Chamber Material |
16mm Q245R boiled steel |
4 |
Daily Capacity (24H) |
30-300MT |
5 |
Condensers |
Q235R |
6 |
Fuels Choice |
Oil, gas, coal |
7 |
Power |
70kw/h |
8 |
Cooling Method |
Cycle Water(70M3) |
9 |
Delivery Time |
1 month |
10 |
Type of Installation |
With foundation |
11 |
Installation Area (m) |
25m*35m |
12 |
Noise dB(A) |
≤85 |
13 |
Operating Mode |
Continuous |
14 |
Sync Gas Treatment |
Fully burned as fuel |
15 |
Manpower |
3~4 per shift |
16 |
Total weight(MT) |
100mt |
17 |
Shipment |
8*40HC |
Continuous Waste Engine Oil Distillation Plant
Continuous Distillation,Continuous Distillation Column,Waste Oil Refinery
Shangqiu Jinpeng Industrial Co., Ltd. , http://www.recyclingthewaste.com